Actuator technical downloads

Download available ZHR-H and ZHR-P catalog PDFs, STEP CAD and dimension images. Select the exact model and confirm the document revision, reduction ratio, interface and mounting configuration before releasing your design.

Engineering Boundary & Verification Note:

These files support preliminary selection. A file's availability does not establish that it matches every order configuration. CAD and dimension images are not substitutes for an approved production drawing.

Public torque ranges by model; ranges depend on reduction ratio. Source: ZHR-H specification sheets.
Model / resource Rated / peak torque 2D reference 3D file
ZHR-H14 5–14 / 15–46 Nm Dimension image STEP CAD
ZHR-H17 13–43 / 40–122 Nm Dimension image STEP CAD
ZHR-H20 20–64 / 50–170 Nm Dimension image STEP CAD
ZHR-H25 27–91 / 63–210 Nm Dimension image STEP CAD
High Dynamics Planetary Modules

ZHR-P planetary actuator files

Two catalog files are present. Their revision relationship is not established here; neither is identified as the latest revision. Request the catalog applicable to your selected configuration if values differ.

Configuration Boundary Checked 18 September 2026

ZHR-P17: choose the 36 V or 48 V configuration

ZHR-P17 is available in two configurations: 36 V with one magnetic encoder, and 48 V with two magnetic encoders. Specify the required configuration in your inquiry. The table below quotes the corresponding catalog entries; confirm the applicable drawing and document revision for your order. PDF creation dates do not establish engineering revision approval.

Configuration comparison checked 18 September 2026
Parameter 36 V / single encoder — Catalog A, page 4 48 V / dual encoder — Catalog B, page 3
Rated voltage 36 V 48 V
Voltage range 24–48 V 24–60 V
Magnetic encoders 1 pc 2 pcs
No-load speed 315 rpm ± 10% 410 rpm ± 10%
Rated-load speed 275 rpm ± 10% 100 rpm ± 10%

Both documents list 6 Nm rated and 17 Nm peak torque, 380 g ± 3 g mass and a 7.75:1 reduction ratio. Request written confirmation of the ordered configuration, drawing revision, voltage, encoder and torque-speed conditions. Do not combine values from different documents into one specification.

Public model torque summary. Source: ZHR-P specification sheets. Peak torque is not a continuous-duty or impact-load rating.
Model / resource Rated / peak torque 2D reference 3D file
ZHR-P05 1.6 / 5.5 Nm Dimension image STEP CAD
ZHR-P14 5 / 14 Nm Dimension image STEP CAD
ZHR-P17 6 / 17 Nm Dimension image STEP CAD
ZHR-P36 11 / 36 Nm Dimension image STEP CAD
ZHR-P60 20 / 60 Nm Dimension image STEP CAD
ZHR-P120 40 / 120 Nm Dimension image STEP CAD
Bus & Communication Verification

Communication and document status

What the public pages establish, and what still needs configuration confirmation
Item Public status Required confirmation
H14 / H17 / H20 / H25 interface CAN / RS485 in H-series sheets Selected option, command set, pinout and firmware. CANopen and EtherCAT support are not established.
P60 interface CAN only; no native EtherCAT. See P60 resource. Firmware, command set, pinout and controller compatibility
Other P-series interfaces Model-specific; confirmation required Exact model's interface and firmware; do not infer from P60
Catalogs, CAD and dimension images Files linked above Revision, dimensional tolerances and matching order configuration
Model-specific protocol / pinout manuals Not listed as verified model-specific downloads here Request the exact model and firmware documentation
Thermal, lifetime and load-test reports Availability requires confirmation Test conditions, duty cycle, cooling, loads and applicability

A CAN interface does not by itself specify CANopen. An external gateway does not make an actuator natively EtherCAT-compatible.

Engineering Support & RFQ

Request the documents for your design

Actuator Inquiry Checklist (.TXT)

Download the actuator inquiry checklist (TXT) and use it to prepare your project requirements.

Download Checklist (TXT)

Include the model, reduction ratio where applicable, required interface, controller, firmware if known, requested file type and intended application. For thermal or load data, add torque, speed, duty cycle and cooling conditions.

The engineering team must confirm file availability and the matching configuration. Submission does not guarantee immediate delivery of a specific file.